B-10
Redline Management Suite Administration and Maintenance Guide
Redline Communications Inc. Confidential and Proprietary
CRITICAL: Cable
Compensation Failed
The cable compensation procedure
initiated at startup, has failed.
Repeat the procedure, if the cable compensation
procedure fails again, consider replacing the
cable. See “Interface (IF) Cable” on page 4-6.
The cable compensation-related messages are
not displayed when HTB is used.
CRITICAL: High Power Radio
FPGA loading Failed
After the ODU upgrade, the new
firmware cannot be loaded into the
ODU FPGA.
The default firmware is re-loaded.
This message is displayed when the default
image cannot be loaded after an ODU upgrade
failure.
If this event repeat itself and the upgrade cannot
be completed successfully, then contact
[email protected].
CRITICAL: IF Cable
Disconnected
The IF cable between the IDU and
ODU has been disconnected.
If this was not done intentionally for maintenance
purposes, then ensure that you do not have any
loose connections at the radio or the IDU. See
“Interface (IF) Cable” on page 4-6.
CRITICAL: IF PLL Error
The IF chain has encountered a PLL
error. Communication with the ODU
has been interrupted.
This may be a hardware problem with the ODU.
Please contact
[email protected].
CRITICAL: IF PLL Error
The IF chain has encountered a PLL
error. Communication with the ODU
has been interrupted.
This may be a hardware problem with the ODU.
Please contact
[email protected].
CRITICAL: LO[X] Error
There has been a hardware problem
with local oscillator 1 or 2.
There is a problem on the AN100U/UX’s ODU.
See “LO1, LO2 and Radio Reference Frequency
Errors” on page 5-21.
CRITICAL: ODU Temperature
is too High
The operating temperature of the
AN100U/UX ODU is too high to
continue operation.
The IDU will temporarily suspend
operation to avoid damage.
This is most often caused by excessive ambient
temperatures.
CRITICAL: Radio Reference
Frequency Error
There has been a hardware problem
with the synchronization of the ODU’s
reference frequency.
See “LO1, LO2 and Radio Reference Frequency
Errors” on page 5-21
CRITICAL: Rx PLL Error
The IF chain has encountered a PLL
error. Communication with the ODU
has been interrupted.
This may be a hardware problem with the ODU.
Please contact
[email protected].
Flash Erase Operation Failed.
Default Image Selected.
The ODU upgrade process failed.
This message is specific to the AN100UX. Retry
the upgrade procedure. If the upgrade fails again
then contact
[email protected].
Table B-1
AN100U/UX Event Log Messages (continued)
Message
Description
Comment