2-3
Chapter 2 Overview
Redline Communications Inc. Confidential and Proprietary
applications down to -18°C (0°F). It has excellent resistance to abrasion, moisture,
alkalies, acids, corrosion and varying weather conditions (including ultraviolet
exposure).
– Weatherproofing putty. Refer to your local supplier for detailed specifications. The
type of material to be used will depend on your expected weather conditions.
Establishing a Spares Program
In order to minimize possible network downtime, you should stock a few
maintenance-related items with your base station equipment.
Ensure that the spare parts are stored in accordance with the manufacturer's instructions
with regard to temperature, humidity and anti-static requirements
.
Refer the RedMAX Base Station Installation Guidelines for details of the required parts, for
part numbers and ordering information.
Reference Information
You will also need to gather the following network-specific information:
•
Device Configuration including both hardware and software configuration of each
RedMAX device, as well as any other devices that are either physically or logically
connected to your RedMAX devices.
Many network devices make provisions for saving their running configuration to text
format and then storing this file on an FTP server. If that is not an option, you will need
to collect and store screen captures of the necessary configuration screens. Make sure
to include the currently active software versions.
•
Network diagram: That may consist of multiple drawings. Your network diagram must
show the following information.
– The physical connections between network devices;
Table 2-2
AN100U/UX Spare Parts
Part
Description
IF cable
This cable connects the indoor unit (IDU) to the radio.
RF Cable
This cable connects the radio to the antenna.
Fuses
These fuses are located in the IDU to protect the unit from power surges.
SUO/SUI
Subscriber unit, with know characteristics can be used when troubleshooting
and can be used as a replacement for customer devices, as required.
Power Cord
This cord is used to connect the IDU to power outlet
Hardware
You should keep the following items on hand: nuts, bolts, washers and lock
washers for the outdoor unit) to replace damaged or corroded parts.