B-17
Appendix B AN100U/UX Event Log Messages
Redline Communications Inc. Confidential and Proprietary
Synchronization Signal not
Detected
The Slave or Backup Master has
previously been synchronized with a
Master, but has since lost the signal
and may have drifted out of phase.
The Slave will continue transmitting, however its
clock will eventually drift out of phase with the
rest of the sector if synchronization is not
restored.
A Slave, previously synchronized with
a Master, has since lost the signal.
The Slave will continue operating, however its
clock will eventually drift out of phase with the
rest of the sector, if synchronization is not
restored.
Synchronization Signal not
Detected. Waiting...
A sector controller configured as a
Slave cannot detect the
synchronization signal from the
Master or the Backup Master.
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Synchronization with Backup
Failed
A sector controller configured as a
Master, has been rebooted, then
detected the presence of a Backup
Master, but has failed to resume
control of the Backup Master’s clock.
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Synchronization with Backup
Ok
A sector controller configured as
Master, has been rebooted, then
detected the presence of a Backup
Master, and successfully resumed
control of the Backup Master’s clock.
Information only. There is no action required.
Synchronization with GPS is
Lost
Synchronization with a previously
detected external clock source has
been lost
Follow the synchronization installation guidelines
for installation and troubleshooting of local or
GPS synchronization. Refer to the RedMAX
Base Station Installation Guidelines.
Synchronization with GPS Ok
Synchronization with an external GPS
clock has been successfully
completed.
Information only. There is no action required.
Synchronization with Master is
Lost
A Backup Master that previously
detected the presence of a the Master
clock signal, has since lost the signal.
The Backup Master will provide a clock signal for
the rest of the Slave devices within the base
station until the signal from the Master returns.
Please follow the synchronization installation
guidelines for installation and troubleshooting of
local and GPS synchronization.
Synchronization with Master
Ok
A Backup Master has successfully
synchronized with a Master’s clock
signal.
Information only. There is no action required.
Table B-1
AN100U/UX Event Log Messages (continued)
Message
Description
Comment