5.2.14 Reset
Use the
reset
command to set AN-80i data to zero.
Table 27: CLI - reset
PTP PMP Parameter/Description
√
√
Reset AN-80i values.
reset <stats>
stats
- Reset statistics.
5.2.15 Save
Use the
save
command to copy edited parameter settings into non-volatile memory.
save [option] <Enter>
Table 28: CLI - save
PTP PMP Parameter/Description
√
√
Copy parameters to non-volatile memory
save <config> <defaultconfig> <snmp>
config
- Save Ethernet, wireless, and user configuration settings.
defaultconfig
Overwrite parameters with the factory default
settings. The following settings are not affected: system
name, location, details and contact, frequency list, SNMP
configuration, IDs table (PMP only).
snmp
- Save SNMP settings.
5.2.16 Script
Use the
script
command to save a file containing a string of CLI commands that can be
used to restore the current (active) configuration of the AN-80i. Saved configuration files
can be viewed, copied, and/or modified using a text editor.
The file will be saved in the TFTP default directory. The filename may be any name and
extension valid for the TFTP server platform. It is recommended use a filename that
uniquely identifies the An-80i unit and the current date (e.g., Red80-AD0023-
080723.cfg).
See also 'loadscript' command.
Table 29: CLI - script
PTP PMP Parameter/Description
√
√
script <server> <name>
server
TFTP server IP address
name
Script file name