Auto scan
:
Check this box to enable the PTP Slave automatically scan available
channels to locate and register with an AN-80i PTP Master.
Frequency Ranges
:
When the Auto Scan field is checked, click the blue text
[
Frequency Ranges
]
adjacent to the check box to display the Frequency
Management screen. Up to 32 frequency ranges may be entered. Frequency ranges
may be entered on the PTP Master and the PTP Slave. Settings entered on the PTP
Master will be downloaded and used by the PTP Slave.
Figure 19: Web - PTP Frequency Management Screen
Add Frequency Range
Begin
: Enter the lower limit of the frequency scan interval (MHz). The scan interval
must be a subset of the region frequency range. The AN-80i compensates for
channel size when selecting the center frequency.
End
:
Enter the upper limit of the frequency scan interval (MHz). The scan interval
must be a subset of the region frequency range. The AN-80i compensates for
channel size when selecting the center frequency.
Add
: Click to check the range settings and add these to the Local Frequency Range
list (if valid). To save changes to non-volatile memory, return to the Configuration
Screen and click the Save button at the bottom of the screen.
Delete Frequency Range
Index
:
Choose the index value of the scan interval to be deleted from local frequency
range table.
Delete
: Click the Delete button to permanently remove the selected scan interval
from the local frequency range table.