User
AN-80i
Manual
70-00072-01-08b
Proprietary Redline Communications © 2009
Page 106 of 128
June 4, 2009
6.5.2 PMP Status Codes
The PMP status code is displayed in a series of hexadecimal characters representing
the status of different alarm conditions. The value '1' indicates the associated condition
is active. All unused bits are set to zero.
To determine the status, the hexadecimal number must be converted to binary notation.
It is recommended to use a scientific calculator that supports binary notation (e.g.,
Windows on-screen calculator). Set the mode for Hex and enter the status code.
Change the mode to binary and match active bits (1) to the PMP Status Codes table.
For example, if 'Radio Over Temperature' bit 1 and 'PLL Error' bit 4 were active, the
status code value would be Hex '12' (binary 1 0010).
Table 48
:
Diag. - PMP Status Code Bits
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9
8
7 6 5 4 3
2
1
0
Table 49
:
Diag. - PMP Status Codes
Bit Description
1 Radio
over-temperature
4, 5, 6
PLL Errors
8 Firmware
Error
16
No Ethernet packets received by the wireless MAC
17, 18, 19,
20, 21, 22,
23, 24, 25,
26, 27, 28
MAC Internal Errors