The open cable ends are conducted as shown in the figure below.
Figure 1-9
Open Cable Ends of STD 30 Power Supply Cables P1 and P2
1.4.4.3
Ethernet Ports E1 and E2
Figure 1-10 Ethernet Sockets E1 and E2
The 2 RJ45 sockets on the device front are provided for connection to an existing
Ethernet. Spring-loaded hinged covers protect the sockets against dust and splashing
water.
Figure 1-11 Ethernet Plug for E1 and E2
STD 30 Ethernet cables of type UC900 SS27 Cat.7, 4 x 2 x AWG27 S/FTP are used to
connect the Standard 30 MF to the Ethernet. They are equipped with a pre-mounted RJ45
plug Neutrik NE8MC6-MO on the device side as shown in Figure 1-11. The other ends are
fitted with a plug type Telegärtner STX IP20 RJ45 - AWG24-27 CAT.6a. Each cable is
approx. 3 m long.