Standard 30 MF
110-700
Operator and Service Manual
Edition:
1-13
4361.DOC010302 AUG18.DOCX
The pin assignments and factory settings for N1 and N2 are shown in the following tables.
Table 1-1
N1 Pin Assignments
Pin No.
Wire Label
Function /
Factory Settings
37
37 CAN1 H (1)
Connection to CAN bus 1
36
36 CAN1 L (1)
33
33 CAN1 H (2)
CAN bus termination for CAN bus 1
(required if Standard 30 MF is the first or
last device in the CAN bus system)
27
27 CAN1 L (2)
32
32 CAN1 GND
Ground for CAN bus 1
7
7 ROT +/-10V
+/- 10 V for analog
rate of turn indicator
3
3 ROT 0V
0 V for analog
rate of turn indicator
22
22 K1 NC
Status relay "System Fault"
(normally closed)
28
28 K1 CO
Status relay "System Fault"
(common)
21
21 K1 NO
Status relay "System Fault"
(normally open)
6
6 Rx+ 4
not used
12
12 Rx- 4
5
5 Tx+ 4
Serial output 4 (Port 4)
Telegrams: HETHS, HEROT
Baudrate: 38400bd
Update rate: 50Hz
10
10 Tx- 4
11
11 RS4 GND
Ground for serial port 4