![Raytheon Standard 30 MF Operator'S And Service Manual Download Page 83](http://html.mh-extra.com/html/raytheon/standard-30-mf/standard-30-mf_operators-and-service-manual_791367083.webp)
Standard 30 MF
110-700
Operator and Service Manual
Edition: 8
2-47
4361.DOC010302 AUG18.DOCX
2.5.4.2
Ethernet Port 2
Table 2-10
Output Data - Telegram, Activation and Refresh Rate for Ethernet 2
Telegram
Activated?
Refresh Rate
HEHDT
ON /
OFF
1 Hz /
10 Hz /
50 Hz
HETHS
ON /
OFF
1 Hz /
10 Hz /
50 Hz
HEROT
ON /
OFF
1 Hz /
10 Hz /
50 Hz
HEHCR
ON /
OFF
1 Hz /
10 Hz /
50 Hz
TIROT
ON /
OFF
1 Hz /
10 Hz /
50 Hz
PANZHRP
ON /
OFF
1 Hz /
10 Hz /
50 Hz
2.5.5
CAN Output Data Settings
Table 2-11
CAN Output Data - Activation and Output Rate
Parameter
Activated?
Output Rate
Attitude and heading output
ON /
OFF
10 Hz /
50 Hz
2.5.6
Angular Rates Output Settings
Table 2-12
Angular Rates Output - Damp Values
Parameter
Set Value
Cut-off frequency of the RoT low-pass filter
________ Hz
Cut-off frequency of the roll and pitch rate filters
________ Hz
Table 2-13
Angular Rates Output - Output Range for RoT
Parameter
Value Range
Cut-off frequency of the RoT low-pass filter
30 °/min /
100 °/min /
300 °/min