2.3
Installation Instructions
The Standard 30 MF can be mounted standing on the floor or
hanging from the ceiling.
When selecting the installation location, required clearances around
the unit have to be considered as shown in the Standard 30 MF
dimensional drawing 110-700.HP005 in the annex.
Four attachment drill holes with a diameter of 6.6 mm are located in
the bottom of the housing as shown in the following figure.
Figure 2-2
Standard 30 MF, Attachment Drill Holes
The connecting sockets are located on the front of the Standard 30 MF. The type of
installation and the installation direction have to be specified during setting to work; the
side with the connecting sockets shows the installation direction.
The Standard 30 MF is provided with a pre-installed ground strap on
the housing side. The overall length of the ground strap between the
center points of the attachment drill holes is approx. 195 mm.
A
A
A-A
10
11
0
145
17,5
240
6
220
∅
6,6
∅
11