Hydraulic System
Installation
Preparing for Installation
Important:
Refer to the implement’s operation manual before changing the connection or configuration of any of
the existing hydraulic hoses.
For the OmniRow system to function properly, its hydraulic tank line must connect to a low pressure return
connection on the tractor that prohibits the tank pressure from exceeding 200 psi. A motor return connection is
the ideal connection for the OmniRow system because it prevents the pressure from being reversed to the
system. The vacuum fan motor on the planter is often installed on this connection. If this is the case, it is likely
that the fan return line can be connected to the SCV return port next to the fan pressure line. If there is no
available return connection, one will have to be added to the tractor. Contact your local tractor service provider
for more information.
FIGURE 1.
Low Pressure Motor Returns