![background image](http://html.mh-extra.com/html/raven/omnirow/omnirow_installation-manual_788985029.webp)
4
Manual No. 016-3001-012
25
Wiring Installation
FIGURE 3.
Seed Tube Sensor Connection
6.
Connect the remaining 3-pin weatherpack connector to the installed seed tube sensor on the first row unit.
7.
Repeat steps 4 - 6 above to connect the harness cables to the remaining row units.
8.
Install the power/CAN extension cable on the remaining receptacle connector on the left harness cable.
9.
Route the extension cable along the planter’s draw bar (along with the installed pressure and tank hoses).
10.
Connect the extension cable to the installed tractor harness cable.
11.
Secure the installed cables with cable ties or hose clamps.
Install the Proximity Switch
FIGURE 4.
Proximity Switch Installed