![background image](http://html.mh-extra.com/html/raven/omnirow/omnirow_installation-manual_788985028.webp)
Chapter 4
24
White MultiRow OmniRow™ Installation Manual
Install the OmniRow Harness Cables
Note:
On planters equipped with 24 planter row units, the harness cable is divided in half. The left
harness cable and right harness cable connect together at the middle of the planter. Locate the
cable connectors on each harness cable to determine which ends of the harness cables are
installed on the end row units of the planter. On planters equipped with 16 row units or less, the
harness cable is a single cable.
1.
Lay the left harness cable along the length of the left side of the planter, aligning the motor, PWM valve, and
seed sensor cables with their corresponding row unit.
Note:
The harness cable should be laid on top of the installed hydraulic hoses.
2.
Lay the right harness cable along the length of the right side of the planter, aligning the motor, PWM valve,
and seed sensor cables with their corresponding row units.
3.
Connect the female receptacle connector from the left harness cable to the male receptacle connector of
the right harness cable.
FIGURE 2.
Harness Cable Connections on the Row Units
4.
Connect the 3-pin metripack connector labeled Section 1 to the motor speed sensor of the hydraulic motor
installed on the first row unit.
5.