![background image](http://html.mh-extra.com/html/raven/omnirow/omnirow_installation-manual_788985014.webp)
Chapter 3
10
White MultiRow OmniRow™ Installation Manual
Install the PWM Valve and Fittings on the OmniRow Hydraulic
Motor
FIGURE 7.
PWM Valve and Fittings Installed
1.
Install the PWM valve assembly in the pressure port of the OmniRow hydraulic motor (P/N 416-8000-001).
2.
Install a 3/4” SAE O-ring (M) to 3/4” JIC (M) straight adapter fitting (P/N 333-0012-093) in the tank port of
the OmniRow hydraulic motor.
3.
Middle Row Units Only - Install a 3/4” JIC M/M/F swivel run tee adapter fitting (P/N 333-0012-039) on the
fitting installed in the tank port of the OmniRow hydraulic motor.
Install the Drive Couplers
1.
Based on the planter’s configuration, determine which side of the hydraulic motor will drive the hex shaft.
FIGURE 8.
Drive Coupler Assembly
2.
Insert the coupler (P/N 107-0172-043) into the side of the motor that will drive the hex shaft.
3.
Install the hex spacer (P/N 107-0172-017) in the opposite side of the motor.
4.
Insert a 1/4”-20 UNC-2 x 3-1/2” bolt (P/N 311-0050-115) in the shaft coupler and through the hex spacer.
5.
Install a 2” OD x 1/4” ID washer (P/N 313-2300-136) on the bolt.
6.
Secure the assembly with a 1/4”-20 zinc flanged lock nut (P/N 312-1001-168). The final assembly should
appear as shown in Figure 9 below:
Middle Row Unit Assembly
End Row Unit Assembly
P/N 333-0012-039
P/N 333-0012-093
P/N 311-0050-115
P/N 107-0172-043
P/N 107-0172-017
P/N 313-2300-136
P/N 312-1001-168