![background image](http://html.mh-extra.com/html/raven/omnirow/omnirow_installation-manual_788985030.webp)
Chapter 4
26
White MultiRow OmniRow™ Installation Manual
Refer to the supplied Remote Implement Proximity Switch Installation Sheet (P/N 016-0171-374) to install the
proximity switch with the parts provided.
Note:
The proximity switch brackets can be assembled in multiple configurations to fit various models of
planters. Not all of the supplied brackets may be required for installation.
Install the OmniRow Nodes
FIGURE 5.
OmniRow Node Installed
Note:
The node mounting plate has several options for mounting the magnets. Determine the best node
mounting position(s) appropriate for the machine’s configuration.
1.
Install three 1/4”-20 x 3/4” HD hex bolts (P/N 311-0049-103) in the desired holes of the node mounting
plate(s) using three 1/4”-20 UNC nylon insert lock nuts (P/N 312-4000-057).
2.
Mount the OmniRow node(s) (P/N 063-3001-001) to the node mounting plate(s) (P/N 107-0171-897) using
three 3/8”-16 x 1” HD hex bolts (P/N 311-0054-105) and three 3/8”-16 nylon insert lock nuts (P/N 312-4000-
061).
3.
Mount the magnets (P/N 418-0000-013) to the previously installed 1/4”-20 x 3/4” HD hex bolts using three 1/
4”-20 flanged lock nuts (P/N 312-1001-168).
Note:
Position the node so that the cable connections face down or to the side.
4.
Insert the large, rectangular node connectors on the harness cables into the correct ports of the OmniRow
node(s).
5.
Tighten the bolts on the node connectors to secure the connections.
Important:
Do not over-tighten the node connections. Over-tightening can cause poor connections, resulting in
substandard system performance.
System Installation Verification
1.