Final
Adjustments
Adjust
the
Constant
Current
Sources
1.
Measure the resistance across resistor R29 and adjust potentiometer R30 so that the
resistance across R29 is 25
Ω
.
————————————————————————————
2.
Measure the resistance across resistor R33 and adjust potentiometer R34 so that the
resistance across R33 is 25
Ω
.
————————————————————————————
3.
Measure the resistance across resistor R37 and adjust potentiometer R38 so that the
resistance across R37 is 100
Ω
.
————————————————————————————
4.
Measure the resistance across resistor R42 and adjust potentiometer R43 so that the
resistance across R42 is 100
Ω
.
————————————————————————————
5.
Measure the resistance across resistor R47 and adjust potentiometer R48 so that the
resistance across R47 is 100
Ω
.
————————————————————————————
6.
Measure the resistance across resistor R52 and adjust potentiometer R53 so that the
resistance across R52 is 100
Ω
.
————————————————————————————
7.
Install a 6N6P tube in locations V1 and V2.
————————————————————————————
8.
Power on the Active Output and allow it to warm up for about one minute.
————————————————————————————