User Interfaces
MM200 High-Speed Microwave Modem
4-34
TM086 - Rev. 4.1
4.5.4 Global Response Operational Codes
In acknowledgment response packets, the operational code <OPCODE> field of the message
packet is set to 0 by the receiving devices when the message intended for the device is evaluated
as valid. The device that receives the valid message then exchanges the <SOURCE ID> with the
<DESTINATION ID>, sets the <OPCODE> to zero in order to indicate that a good message was
received, and returns the packet to the originator. This "GOOD MESSAGE" Opcode is one of
nine global responses. Global response Opcodes are common responses, issued to the M&C
computer or to another device, that can originate from and are interpreted by all Radyne Inc.
equipment in the same manner. These are summarized as follows all Opcode values are
expressed in decimal form:
Table 4-5. Response OPCODES
RESPONSE OPCODE DESCRIPTION
OPCODE
Good Message
000d = 0x0000
Bad Parameter
255d = 0x00FF
Bad Opcode
254d = 0x00FE
Bad Checksum
253d = 0x00FD
Command Not Allowed in LOCAL Mode
252d = 0x00FC
Command Not Allowed in AUTO Mode
251d = 0x00FB
Bad Destination
250d = 0x00FA
Unable to Process Command
249d = 0x00F9
Packet Too Long
248d = 0x00F8
The following response error codes are specific to the MM200:
MM200 Response Error Code Descriptions
OPCODE
REMOTE_GOOD
0x0000
REMOTE_SIZE_ERROR
0x0201
REMOTE_UNKNOWN_ERROR
0x0202
REMOTE_CONTROL_ERROR
0x0203
REMOTE_PARAMETER_ERROR
0x0204
REMOTE_LASTRATE_ERROR
0x0205
REMOTE_SYMBOL_LO_ERROR
0x0206
REMOTE_SYMBOL_HI_ERROR
0x0207
REMOTE_DATA_LO_ERROR
0x0208
REMOTE_DATA_HI_ERROR
0x0209
REMOTE_FRAMING_ERROR
0x020A
REMOTE_MODULATION_ERROR
0x020B
REMOTE_DEMODULATION_ERROR
0x020C
REMOTE_CHANNEL_ERROR
0x0210
Summary of Contents for MM200
Page 2: ......
Page 14: ...Introduction MM200 High Speed Microwave Modem 1 2 TM086 Rev 4 1...
Page 18: ...Installation MM200 High Speed Microwave Modem 2 2 TM086 Rev 4 1...
Page 24: ...Theory of Operation MM200 High Speed Microwave Modem 3 6 TM086 Rev 4 1...
Page 76: ...User Interfaces MM200 High Speed Microwave Modem 4 52 TM086 Rev 4 1...
Page 93: ...MM200 High Speed Microwave Modem Electrical Interfaces TM086 Rev 4 1 5 17...
Page 96: ...Troubleshooting and Maintenance MM200 High Speed Microwave Modem 6 4 TM086 Rev 4 1...
Page 99: ...Technical Specifications MM200 High Speed Microwave Modem 7 2 TM086 Rev 4 1...
Page 100: ......
Page 147: ...MM200 High Speed Microwave Modem Appendix A TM086 Rev 4 1 A 47...
Page 148: ......
Page 186: ...Appendix B MM200 High Speed Microwave Modem B 38 TM086 Rev 4 1...
Page 192: ...Glossary MM200 High Speed Microwave Modem G 6 TM086 Rev 4 1...