MM200 High-Speed Microwave Modem
Appendix B
TM086 – Rev 4.1
B-15
radMM200TxInterfaceLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Minor Alarm status:
Bit 0 = Interface FIFO full
Bit 1 = Interface FIFO empty
Bit 2 = Interface PLL lock
Bit 3 = Interface data activity detect
Bit 4 = Interface clock activity detect
Bit 5 = Interface Tx input framing valid, added for AASI
Bit 6 = Interface signal loss, valid for some interfaces
Bit 7 = Spares
0 = Pass, 1 = Fail"
::= { radMM200TxInterfaceStatusEntry 5 }
radMM200TxInterfaceCard OBJECT-TYPE
SYNTAX INTEGER {
none(1),
asi_aasi(2),
nasi(3),
t3e3(4),
t1e1(5),
ds0(6),
parallel(7),
oc3(8),
hssi(9),
smpte(10)
}
MAX-ACCESS
read-only
STATUS current
DESCRIPTION
"Interface card type."
::= { radMM200TxInterfaceStatusEntry 6 }
-- --------------------------------------------------------------------------------------------------------------------
-- --------------------------------------------------------------------------------------------------------------------
-- MM200 demodulator non-volatile status information.
radMM200RxIFFrequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF frequency in Hz. This is the center
frequency of the aggregate; the edge frequency,
however, is dependent on the number of channels,
symbol rate, and spacing. The frequency range
of the MM200 is 50MHz to 90MHz."
::= { radMM200DemodNVStatus 1 }
radMM200RxIFUser1Frequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF user 1 frequency in Hz."
::= { radMM200DemodNVStatus 2 }
radMM200RxIFUser2Frequency OBJECT-TYPE
SYNTAX INTEGER (50000000..90000000)
MAX-ACCESS
read-write
STATUS current
DESCRIPTION
"Selects IF user 2 frequency in Hz."
::= { radMM200DemodNVStatus 3 }
Summary of Contents for MM200
Page 2: ......
Page 14: ...Introduction MM200 High Speed Microwave Modem 1 2 TM086 Rev 4 1...
Page 18: ...Installation MM200 High Speed Microwave Modem 2 2 TM086 Rev 4 1...
Page 24: ...Theory of Operation MM200 High Speed Microwave Modem 3 6 TM086 Rev 4 1...
Page 76: ...User Interfaces MM200 High Speed Microwave Modem 4 52 TM086 Rev 4 1...
Page 93: ...MM200 High Speed Microwave Modem Electrical Interfaces TM086 Rev 4 1 5 17...
Page 96: ...Troubleshooting and Maintenance MM200 High Speed Microwave Modem 6 4 TM086 Rev 4 1...
Page 99: ...Technical Specifications MM200 High Speed Microwave Modem 7 2 TM086 Rev 4 1...
Page 100: ......
Page 147: ...MM200 High Speed Microwave Modem Appendix A TM086 Rev 4 1 A 47...
Page 148: ......
Page 186: ...Appendix B MM200 High Speed Microwave Modem B 38 TM086 Rev 4 1...
Page 192: ...Glossary MM200 High Speed Microwave Modem G 6 TM086 Rev 4 1...