![Radyne MM200 Installation And Operation Manual Download Page 54](http://html1.mh-extra.com/html/radyne/mm200/mm200_installation-and-operation-manual_3378873054.webp)
User Interfaces
MM200 High-Speed Microwave Modem
4-30
TM086 - Rev. 4.1
FW4459--
FW4459--
Firmware Version
Firmware Date
RO
RO
RO
RO
RO
RO
4.4.10 TEST (Menu)
The Test Screens are listed below:
Screen Name
Selections and Descriptions
L0
L1
L2
LED TEST
{On, Off}
Illuminates all LEDs on front panel.
RW
RW
RW
MUX DMX LOOP
{Normal, Mux Dmx Loop, Mux, Dmx
LVDS, Modem LVDS, Repeater}
Tests multiplexer and demultiplexer
function.
RW
RW
RW
RF LOOPBK
{NORMAL, LOOPBACK}
Tests modulator and demodulator
function.
RW
RW
RW
CARRIER
{Normal, CW, Offset 1 Hz, 100 kHz, 3.5
MHz, Sweep Up, Sweep Dn}
Sets the carrier to normal pure carrier
output, or sweep test modes.
RW
RW
RW
PRBS:
{None, 2
15
, 2
15
M, 2
23
, 2
23
M}
Breaks the data path and inserts a pseudo
random sequence into the modulators.
‘None’ is used for normal operation, the
others are for Radyne Inc. configuration.
RW
RW
RW
REMOTE TAPS
{NORMAL, 1:1, 1:10, 1:100}
Remote Tap Enable
RW
RW
RW
AGC BW
{6}
Set to 6 for normal operation.
RW
RW
RW
4.5 Remote Port User Interface
The Remote Port of the MM200 allows for complete control and monitor functions via an RS-485
Serial Interface.
Control and status messages are conveyed between the MM200 and the subsidiary modems, and
the host computer using packetized message blocks in accordance with a proprietary
communications specification. This communication is handled by the Radyne Link Level Protocol
(RLLP), which serves as a protocol ‘wrapper’ for the M&C data.
Complete information on monitor and control software is contained in the following sections.
Summary of Contents for MM200
Page 2: ......
Page 14: ...Introduction MM200 High Speed Microwave Modem 1 2 TM086 Rev 4 1...
Page 18: ...Installation MM200 High Speed Microwave Modem 2 2 TM086 Rev 4 1...
Page 24: ...Theory of Operation MM200 High Speed Microwave Modem 3 6 TM086 Rev 4 1...
Page 76: ...User Interfaces MM200 High Speed Microwave Modem 4 52 TM086 Rev 4 1...
Page 93: ...MM200 High Speed Microwave Modem Electrical Interfaces TM086 Rev 4 1 5 17...
Page 96: ...Troubleshooting and Maintenance MM200 High Speed Microwave Modem 6 4 TM086 Rev 4 1...
Page 99: ...Technical Specifications MM200 High Speed Microwave Modem 7 2 TM086 Rev 4 1...
Page 100: ......
Page 147: ...MM200 High Speed Microwave Modem Appendix A TM086 Rev 4 1 A 47...
Page 148: ......
Page 186: ...Appendix B MM200 High Speed Microwave Modem B 38 TM086 Rev 4 1...
Page 192: ...Glossary MM200 High Speed Microwave Modem G 6 TM086 Rev 4 1...