1269 User Manual
Using The Enhanced Monitoring System 4-28
Table 4-8 Front Panel Status Messages
Message
Meaning
System OK
AC Power switch is ON, nothing out-of-tolerance
Standby
AC power switch is OFF, nothing out-of-tol
+5V PS OV
+5V power supply over-voltage condition
-5V PS OV
-5.2V power supply over-voltage condition
-2V PS OV
-2V power supply over-voltage condition
+24V PS OV
+24V power supply over-voltage condition
-24V PS OV
-24V power supply over-voltage condition
+12V PS OV
+12V power supply over-voltage condition
-12V PS OV
-12V power supply over-voltage condition
+5V PS UV
+5V power supply under-voltage condition
-5V PS UV
-5.2V power supply under-voltage condition
-2V PS UV
-2V power supply under-voltage condition
+24V PS UV
+24V power supply under-voltage condition
-24V PS UV
-24V power supply under-voltage condition
+12V PS UV
+12V power supply under-voltage condition
-12V PS UV
-12V power supply under-voltage condition
FAN SPEED
Fan speed is out of tolerance
AMB TEMP H
Ambient Temperature is too high
SLOT XX T
Slot XX temperature rise is too high
(XX will be “C0 to C5", or “B0 to B2")
IACKX CNT
Interrupt Acknowledge Line X count reached
(X will be “1" to “7")
BERR CNT
Bus Error count reached
SYSFAIL
SYSFAIL* line asserted
ACFAIL
ACFAIL* line asserted
PON TIME
Elapsed power-on time limit reached
TOT PON TM
Elapsed cumulative power-on time limit reached
FILTER
Filter service time limit reached