1260-00C User Manual
Local Command Set 4-27
DCON?
query returns configuration information about a device.
The
DRES?
query is used to perform a soft-reset sequence on a
device.
The
RREG?
query and
WREG
command are used to peek (read
from) and poke (write to) registers on a VXI device.
DCON?
Purpose:
Return system configuration information about a
device or all devices.
Query
Syntax:
DCON? [<logical address>]
(If
<logical address>
is omitted,
DCON?
returns the configuration information for all devices.)
Response:
Program response:
<la1>,<cla>,<IHANS>,<INTS>,<status>,<s
state>,<com>
<CRLF>
Console response:
Device configuration at Logical
Address <la>
:<CRLF>
<CRLF>
Commander's Logical Address:<cla>
<CRLF>
Interrupt Handlers
:<IHANS>
<CRLF>
Interrupters
:<INTS>
<CRLF>
Passed/Failed/Ready
:<status>
<CRLF>
Device Substate
:<sstate>
<CRLF>
Manufacturer Specific Comment
:<com>
<CRLF>
The mnemonics have the following meanings:
la
Device's logical address
cla
Commander's logical address
IHANS
Interrupt handler levels used by this
device where
IHANS
is a 7-digit
binary representing the seven VXI
interrupt levels and a 1 in each
position, meaning Interrupt Handler
present
INTS
Interrupter levels used by this device