![Racal Instruments 1260-00C User Manual Download Page 106](http://html1.mh-extra.com/html/racal-instruments/1260-00c/1260-00c_user-manual_3123646106.webp)
1260-00C User Manual
Local Command Set 4-57
input to counter:
Value Trigger Line
0 to 7
TTL trigger lines 0 to 7
8 to 9
ECL trigger lines 0 to 1
70
CLK10
71
EXTCLK
and
<count>
specifies the number of input pulses
to count before terminating.
Response:
Program response: 0
Console response:
CNTR configured (mode = <mode text>,
source = <source text>, count =
<count>).
<CRLF>
where the meaning of
<mode text>
corresponds
to the value of
<mode>
:
Value of
<mode>
Value of
<mode text>
0
INIT
2
RELOAD
3
DISABLE
and the meaning of
<source text>
corresponds
to the value of
<source>
:
Value of
<source>
Value of
<source text>
0 to 7
TTL <line>
8 to 9
ECL (<line> - 8)
70
CLK10
71
EXTCLK
Example :
Configure the counter count 25 assertions on TTL
trigger line 5 (the
<protocol>
parameter when
calling
EnaTrigSense
will determine whether the
counter accepts SYNC or SEMI-SYNC assertions).
TrigCntrConf 0, 5, 25
TrigExtConf
Purpose:
Configure the external trigger (GPIO) lines.
Query
Syntax:
TrigExtConf <extline>, <mode>
where the value of
<extline>
is the trigger line to
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com