UMTS/HSPA Module Series
WCDMA UGxx AT Commands Manual
WCDMA_UGxx_AT_Commands_Manual Confidential / Released 50 / 247
If the temperature did not rise to a degree greater than the lowest temperature within 5 seconds, the
module will be turned off automatically. When the temperature is greater than the lowest temperature limit,
but lower than the low temperature warning limit, the module will output:
+QIND: "temp",-1
When temperature is greater than the highest temperature limit, the module will output:
+QIND: "temp",2
If the temperature did not drop to a degree lower than the highest temperature limit within 5 seconds, the
module will be turned off automatically.
When the temperature is lower than the highest temperature limit, but greater than the high temperature
warning limit, the module will output:
+QIND: "temp",1
When the temperature comes back from the low temperature warning limit or the high temperature
warning limit to normal temperature range, the module will output:
+QIND: "temp",0
The configuration will be stored to NV automatically.
AT+QCFG="temp" Temperature Detection
Write Command
AT+QCFG="temp"[,<temptype>[,<tem
pvalue>[,<temponoff>]]
Response
If configuration parameters are omitted
(
+QCFG="temp"
), return current configuration:
+QCFG: "temp",
(<temptype>,<tempvalue>,<temponoff>),
(<temptype>,<tempvalue>,<temponoff>),
…
OK
If configuration parameters are entered:
OK
ERROR
If error is related to ME functionality:
+CME ERROR: <err>
Maximum Response Time
300ms