M10 AT Commands Set
M10_ATC_V1.01
- 162 -
L=”SQ”,1
20
Forbidden network available
only
AT+QEXTUNSO
L=”FN”,1
21 +CMWT:<store>,<index>,<voic
e>,<fax>,<email>,<other>
Messagewaiting AT+QEXTUNSO
L=”MW”,1
22
+CGURC:<event>
Unsolicited result code follow
particular call state transition
AT+QEXTUNSO
L=”UR”,1
23 +CBCN<bcs>,<bcl>
Display
battery
connextion
status and battery charge level
AT+QEXTUNSO
L=”BC”,1
24
+QBAND:<band>
Band mode display
AT+QEXTUNSO
L=”BM”,1
25 +TSMSINFO:<CMS
error
info>
Additional SMS information
AT+QEXTUNSO
L=”SM”,1
26 +CCINFO:<Call
is
Disconnected>,<remain calls>
Displays the disconnected call
ID and the remain call numbers
after one of the call
disconnected
AT+QEXTUNSO
L=”CC”,1
27
RING
Indicates incoming call
n/a
28
Call Ready
Device ready to make/receive
calls
n/a
29
Charging in NORNAL MODE
The module is in charging state
n/a
30
From GHOST MODE to
NORMAL MODE
Device is turned on when in
charging state
n/a
31
+QTEMP:-1
Low temperature warning
AT+QTEMP=1
32 +QTEMP:1
High
temperature
warning
AT+QTEMP=1
33
+QTEMP:-2
Low temperature shutdown
indicator
AT+QTEMP=1
34
+QTEMP:2
High temperature shutdown
indicator
AT+QTEMP=1
35 UNDER_VOLTAGE
POWER
DOWN
Under voltage shutdown
indication
n/a
36 UNDER_VOLTAGE
WARNING
Under voltage warning
n/a
37 OVER_VOLTAGE
POWER
DOWN
Over voltage shutdown
indication
n/a
38 OVER_VOLTAGE
WARNING
Over
voltage
warning
n/a
39 UNDER_VOLTAGE
POWER
DOWN
Normal power down
n/a
40 +COLP:<number>,<type>[,<sub
addr>,<satype>[CLI validity]],
The presentation of the
COL(connected line) at the TE
for a mobile originated call
AT+COLP=1
41 +CLIP:<number>,<type>””,,<al
phaID>,<CLI validity>
Mobile terminating call
indication
AT+CLIP=1
42
+CRING:<type>
An incoming call is indicated to AT+CRC=1
Quectel