M10 AT Commands Set
M10_ATC_V1.01
- 49 -
Reference
GSM 07.07 [13]
Note
3.2.17 AT+CKPD Keypad Control
AT+CKPD Keypad Control
Test Command
AT+ CKPD=?
Response
OK
Parameters
Write Command
AT+CKPD=[<ke
ys>
[,<time>[,<pause
>]]]
Response
TA emulates ME keypad by giving each keystroke as a character in a
string <keys>. <time>*0.1 seconds is the time to stroke each key and
<pause>*0.1 seconds is the length of pause between two strokes.
Keystrokes <keys> are emulated.
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<keys>
string of characters representing keys as listed in the
following table (based on PCCA STD-101 Annex
table I-3):
Char.:
ASCII-Code:
Note:
#
35
hash (number sign)
*
42
star
(*)
0... 9
48... 57
number keys
:
58
escape character for manufacturer
specific
keys
D/d
68/100
volume
down
E/e
69/101
connection end (END)
R/r
82/114
recall last number (R/RCL/MR)
S/s
83/115
connection start (SEND)
U/u
85/117
volume
up
<time>
0...255 seconds (default value is manufacturer specific, but
should be so long that a normal ME can handle
keystrokes correctly)
<pause>
0... 25.5 seconds
(default value is manufacturer specific, but
should be so long that a normal ME can handle keystrokes correctly)
Reference
GSM 07.07 [13]
Note
3.2.18 AT+CLCC List Current Calls Of ME
AT+CLCC List Current Calls Of ME
Test Command
Response
Quectel