Maintenance
400-294-002
Rev. Date: 01/07
3-29
5. From within the machine, locate the sensor on the front of the base plate near the
waste tank, a shown in Figure 3-30.
6. From under the machine,
unscrew the jam nut on the
sensor. Pull the sensor out of
the hole. Set aside the jam
nut.
7. Unscrew the other jam nut off
the sensor and set it aside.
8. Follow the path of the sensor
wire through the wire harness
to the connector at the back
of the control enclosure. The
connector is the one on the
right in the bottom row, as shown in Figure 3-31.
NOTE
To release the sensor wire from the wire bundle, you can either cut the tie
around the bundle or cut the connector off the end of the sensor wire and pull
the sensor wire out of the bundle.
Figure 3-30
Figure 3-31
Approach
Sensor
Jumper
VacHead
Solenoid
Buffer
Motor
Encoder
Brake
Board
Pin Deck
Sensor
Summary of Contents for Express 294-115-200
Page 2: ......
Page 4: ...ii...
Page 6: ...iv...
Page 80: ...Troubleshooting 4 10 Rev Date 01 07 400 294 002 This page intentionally left blank...
Page 83: ...Parts 400 294 002 Rev Date 01 07 5 3 MISCELLANEOUS...
Page 85: ...Parts 400 294 002 Rev Date 01 07 5 5 294 115 116 Wiring Diagram...
Page 87: ...Parts 400 294 002 Rev Date 01 07 5 7 FRAME and BODY...
Page 107: ...Parts 400 294 002 Rev Date 01 07 5 27 VACHEAD and CLEANING...
Page 117: ...Parts 400 294 002 Rev Date 01 07 5 37 CONDITIONING Oiling and Buffing...