Chapter 4: F2000 Customer Replaceable Units (CRUs)
SSD Assembly Replacement
174
Quantum F2000 User’s Guide
In the example RAS ticket, the
Event Summary
indicates that
drive 07
is degraded. A failed
drive 07
corresponds to an SSD located in
slot 7
at
the front of the F2000 array.
Drive slots are accessible on the front of the F2000 and are numbered
1 through 24 going from left to right (see
Figure 187 F2000 Front View
with Drive Slot Numbering
A degraded SSD displays either a solid or blinking illuminated amber
LED (see
).
Figure 188 LED Location on an
SSD Assembly (Drive in Slot 07
Shown)
Item
LED
Action
1
Drive Fault LED
Amber (solid or blinking): Degraded
drive reported. Replace the drive.
2
Drive Link/Active
• Off: No drive present
• Green: Drive present
• Green (Blinking): Drive active