Chapter 4: F2000 Customer Replaceable Units (CRUs)
Fan Module Replacement
Quantum F2000 User’s Guide
107
7
If the system contains 32 Gb FC cards, disconnect the FC cables from
the FC ports in PCIe slot 1 and PCIe slot 3 on the canister that
contains the failed fan module (see
). Label the cables so
you know how to reconnect them later in this process.
8
Disconnect the CAT6A Ethernet cable that connects Port 4 on the
top canister to port 4 on the bottom canister (see
the cable so you know how to reconnect it later in the process.
Figure 102 Port 4 Canister-to-
Canister Connection
9
Disconnect your the CAT6A Ethernet cable from the IPMI/BMC port
on a canister, if necessary.
10
Unlatch the canister by pulling both of the handles out of the
Item
Description
1
Port 4 on the bottom canister
2
Port 4 on the top canister