UPS
Check the
Enable UPS Support
checkbox to enable UPS supported. Now we support network
UPS via SNMP, Serial UPS with COM port, and USB UPS.
Communication Type:
Now we support network UPS via SNMP, Serial UPS with COM port,
and USB UPS.
Shutdown battery Level:
If the power is shortage, the system will execute shutdown
process when reaching the UPS battery level.
If Communication Type selects SNMP:
SNMP IP Address:
Enter the IP address of the network UPS via SNMP.
SNMP Version:
Select SNMP supported versions: v1, v2c, or v3. Please enter community if
select SNMP v1 or v2c. If select SNMP v3, it needs more options for authentication. Please
enter a username, check to use authentication if necessary, select an authentication
protocol and enter an authentication password, check to use privacy if necessary, the
privacy protocol supports DES, and enter a privacy password.
If Communication Type selects Serial:
UPS Manufacturer:
Select the UPS manufacturer.
UPS Model:
Select the UPS model.
When finished, click the
Apply
button to take effect.
This table shows the UPS status.
Table 9-3 UPS Status Descriptions
COLUMN NAME
DESCRIPTION
UPS Status
The status of UPS:
On Line
: The UPS is online.
On Battery
: The UPS is on battery.
Low Battery
: The voltage of the battery is low.
High Battery
: The voltage of the battery is high.
Replace Battery
: The battery needs to be replaced.