Update Disk Firmware
Select disks by manufacturer or slot, and click the
icon to select a firmware file, and then
click the
Update
button to upgrade the firmware of the disk drive.
CAUTION
If the disk to be updated firmware is a member of the pool and there are
multiple disks of the same model, it is not recommended to update all at the
same time. You need to set one disk to idle and then update the disk
firmware. After completion, perform pool rebuild and then execute the next
disk firmware update. These steps will avoid the risk of data loss.
Instant Erase
For more information, please refer to the
9.4.4.
Power Settings
Click the
Power Settings
pane to configure the boot options and UPS (Uninterruptible Power
Supply).
Boot Management
Click the switch to turn
ON (Enable) or
OFF (Disable).
Auto Shutdown
: Check to enable the auto shutdown feature. If it is enabled, the system will
shut down automatically when the voltage and temperature exceed a critical level.