9.3.1.
Data Port Overview
Storage system provides different type of host connectivity according to the system
configuration, it could be base system or host cards installed system. The host cards must be
installed the same type on both controllers. Currently host card has several types, 10GbE iSCSI
(SFP+)
, 25GbE iSCSI
(SFP28)
, 16Gb FC (SFP+), and 32Gb FC
(SFP28)
for selection according to system
infrastructure.
The
Data Port Overview
displays all the host connectivity in system. The icons show the data
ports connected or disconnected.
9.3.2.
Configure iSCSI Data Ports
Click the
iSCSI Ports
pane to show information of iSCSI ports where they are located (onboard
or host cards).
The columns display information of an connected or disconnected icon,
CTRL
(Controller),
Interface
name,
Location
,
Port
,
Status
,
LAG
(Link Aggregation),
IP address
,
Gateway
IP address,
VLAN ID
(Virtual LAN ID),
Jumbo Frame
status, and
MAC address
.
Click the icon beside the interface to list the drop down options. These options are available
in the iSCSI ports.
Set IP Address
Click the
Set IP Address
option to assign an iSCSI IP address of the iSCSI data port. There are
two options: Use DHCP to acquire an IP address automatically or specify a Static IP Address to
set the IP address manually.
Set Link Aggregation
Click the
Set Link Aggregation
option, the default mode of each iSCSI data port is connected
without any bonding. Two bonding methods, Trunking and LACP (Link Aggregation Control
Protocol), can be selected. At least two iSCSI data ports must be checked for iSCSI link
aggregation.