81
12.6.2 FAN REMOVAL / REPLACEMENT
Oil cooler fans can be removed to check for bearing failures,
jammed fans or to clean/inspect cooler core.
Disconnect the fan connector before attempting to
remove the fan from the shroud.
To remove the fan, unscrew the four bolts using a 4mm
Allen key.
Inspect the fan and ensure that it turns and the fan bearing
has not failed.
If the fan is blowing fuses constantly the motor may be
shorted. Replace the fan.
12.6.3 TEMPERATURE SETTINGS
Depending on the ambient temperature conditions it may
be necessary to adjust the cooler on and off settings.
The cooler on temperature needs to be higher than the
off temperature .
Generally, the cooler on temperature is set for between 40-
50°C (104-122°F) and the off to between 32-40°C (90-
104°F).
In hot ambient conditions, above 35°C (90°F) it’s best to
have the cooler turning on sooner and shutting off later to
ensure the heat load can be managed with higher ambient
air temperatures.