23
Check
the
admix
strainer
for
build
‐
up
that
may
be
impeding
the
flow
of
admixture.
Check
for
loose
inlet
connections
or
any
indication
of
air
in
admix
output.
Air
will
affect
flow
meter
reading
and
be
difficult
to
control.
Is
the
winter
blow
down
valve
closed?
Ensure
the
admix
system
is
primed
sufficiently,
and
lines
are
full.
As
a
final
check
if
the
system
is
in
Admix
Auto
and
generating
an
alarm
go
to
the
Sensor
Calibration
and
then
Flow
Curves
screens.
In
flow
curves
for
the
admix
or
admixes
with
alarms
press
the
Set
Default
button
to
reset
the
flow
curves.
Try
the
admix
in
auto
again.
If
it
still
does
not
work,
you
can
run
the
calibration
and
let
the
computer
generate
the
flow
curve
.
No
admixture
is
flowing:
Is
the
admix
pump
turning?
You
can
generally
hear
or
touch
the
motor
to
see
if
the
pump
is
on.
Check
the
admix
pump
current
in
Electrical
Diagnostics.
Is
there
current
going
to
the
pump?
If
the
current
draw
is
greater
than
10000mA
then
the
pump
may
be
locked
up.
If
your
mixer
has
diaphragm
pumps
disregard.
To
unlock
the
pump,
loosen
slightly
the
four
Philips
screws
If
the
pump
leaks
you
have
gone
too
far.
See
if
the
current
draw
goes
down
and
pump
starts
turning.
Be
careful
not
to
loosen
the
screws
to
far,
you
may
lose
the
O
‐
ring
seal
behind
the
cover
plate.
Once
you
get
flow
moving
through
the
lines
tighten
the
screws
back
up.
Hand
tight
is
all
they
need.
If
the
fluid
is
still
not
moving
and
the
pump
current
draw
is
greater
than
10000mA
then
there
may
be
a
blocked
or
sticking
outlet
check
valve
.
Uncouple
the
quick
connect
fitting
and
try
to
run
the
pump
again.
If
current
draw
drops
and
fluid
starts
to
flow,
then
replace
the
check
valve.
If
the
pump
is
turning
and
current
draw
is
normal
(typically
runs
around
3000
‐
5000mA
depending
on
chemical)
then
the
pump
is
still
not
primed
properly.
Follow
priming
procedure
to
see
if
flow
goes
to
tank
when
valve
is
in
full
bypass
(zero
setting).
Turn
the
valve
back
to
the
wide
‐
open
position
and
see
if
fluid
is
flowing
to
the
water
line.
E
A
B
D
C
B
C
D
E
Summary of Contents for P Series
Page 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Page 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Page 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Page 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Page 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Page 105: ... BATTERY V BATTERY V ...