39
The hydraulic return filter is in bypass.
Change the filter element to see if
alarm goes away. You can confirm the
filter is in bypass by checking the
gauges on the filter housing.
Auger jam alarm. The mix auger
pressure has reached the pressure limit
as entered in the mixer settings screen
and the belt stops. Check to see why
pressure max has been reached (auger
jammed) or increase pressure limit if
need be.
Cement low level sensor activated.
Must override to continue (see Mixer
Control).
Vibrator pulse select indicates the operator
has placed the system in automatic
vibrator select mode. Any of the four
vibrators may be selected to automatically
turn on with the belt.
Water ON is a warning message indicating
that the operator has not turned the water
on (keypad button) before running the belt
in auto mode.
The mixer has been placed in belt unload
mode by the operator. Turn off by pressing
button 10 on the keypad.
The mixer has been placed in cement
unload mode by the operator (see Mixer
Control).
The mixer has been placed in colour unload
mode by the operator (see Mixer Control).
The mixer has been placed in aux1 unload
mode by the operator (see Mixer Control).
The mixer has been placed in aux2 unload
mode by the operator (see Mixer Control).
Summary of Contents for P Series
Page 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Page 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Page 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Page 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Page 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Page 105: ... BATTERY V BATTERY V ...