48
Figure 12. Slotted hole in wear plate towards the upper side of the mix auger
Figure 13. Align slot in seal assembly with grease hole in rear of mix auger frame
8.
Install the remaining bolts so the inner rubber seal (PN AGSL001D) just compresses.
9.
Once installed turn the auger shaft by hand to ensure the shaft spins easily. A small amount of side movement is
expected.
10.
Place anti-seize compound on the idler shaft to help prevent rust buildup and ease future removal of the shaft
from the auger tube.