12.2 AUGER CIRCUIT PRESSURE ADJUSTMENT
IMPORTANT!
The auger valve relief is a load sense relief only and is used to limit the max load sense signal to the pump
compensators. This relief is set lower than the pump pressure compensator to allow the mix auger to continue
to operate when boom, chute and swing functions are at max load sense pressure.
To set the max pressure on the mix auger circuit loosen the
lock nut using a 13mm wrench and turn the load sense
relief all the way in using a #4 Allen key.
Loosen the lock nut on the auger pump pressure
compensator using a 13mm wrench.
With the chute tilt cylinders bottomed out adjust the auger
pump pressure compensator to 3900psi using a 3mm
Allen key. Release chute tilt function. Tighten the lock nut.
With the chute tilt cylinders bottomed out again adjust the
load sense relief until the pressure reads 3600psi.
Release chute tilt function. Tighten the lock nut.
The load sense relief valve setting is now 300psi lower than
the pump compensator pressure.
With auger pump functions all off. Set pump standby
pressure to 320psi by loosening the lock nut on load sense
compensator with 13mm wrench and adjust with 3mm
Allen key.
C
B
A
A
B
A
B
C
Summary of Contents for P Series
Page 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Page 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Page 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Page 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Page 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Page 105: ... BATTERY V BATTERY V ...