74
If the pump is still not pumping or there is still air in the line,
try cracking the strainer bowl slightly to remove any
potential air locks. If fluid is running out and pump is
pumping tighten the bowl.
11.2 STRAINER CLEANING AND REPLACEMENT
IMPORTANT!
A dirty admix strainer will cause the Commander control system to speed up the admix pump when in auto
mode, which will eventually cause it to go into a fault if it can’t meet it’s admix flow target. Check the admix
strainer regularly for buildup.
To remove and inspect the admix inlet strainer unthread the
bowl and pull the strainer out of the housing.
Be careful not to lose the seal .
Clean the strainer as necessary ensuring all debris is
removed and outer mesh is clean.
Clean and dump any debris out of the bowl as well.
If the strainer is plugged beyond reasonable cleaning or it is
damaged, then replace it.
B
A
B
B
A
B
Summary of Contents for P Series
Page 1: ...1 PROALL Mobile Mixer Service Manual P Model MX04703 August 2020 Rev 1 0 ...
Page 20: ...20 has been removed and not replaced then the charge pressure will drop to zero C ...
Page 85: ...International Manufacturing Inc P P1 OUT IN OUT IN 2 1 3 IN S1 S2 2 1 3 OUT IN ...
Page 100: ... ADMIX 1 ADMIX 2 WORK LIGHTS ...
Page 101: ... COOLER 1 VIB1 SPARE VIB1A SPARE VIB2A VIB2 VIB3 VIB4 VIB5 ...
Page 105: ... BATTERY V BATTERY V ...