PRIMES
BeamMonitor BM+ with LDS 2.98
26
Revision 01/2018 EN
10.3.3
Menu overview
File
New
Opens a new file for the measuring data.
Open
Opens a measuring file with the extensions “.foc” or “.mdf”.
Close
Closes the file selected in the tool bar.
Close all
Closes all files opened.
Save
Saves the current file in foc- or mdf format.
Save as
Opens the menu for the storage of the files selected in the tool bar. Only files with the
extensions “.foc” or “.mdf” can be imported safely
Export
Exports all current data in protocol format “.xls” and “.pkl”.
Load measurement
preferences
Opens a file with measurement settings with the extension “.ptx”.
Save measurement
preferences
Opens the menu to save the settings of the last program run. Only files with the
extension “.ptx” can be opened.
Protocol
Starts a protocol of the numeric results. They can either be written into a file or a
data base.
Opens the standard print menu.
Print preview
Shows the content of the printing order.
Recently opened files
Shows the file opened before.
Exit
Terminates the program.
Edit
Copy
Copies the current window to the clipboard.
Clear plane
Deletes the data of the plane selected in the tool bar.
Clear all planes
Deletes all data of the file selected in the tool bar
Change user level...
By entering a password a different user level is activated.
Measurement
Environment
Here, different system parameters can be entered, e.g.
- Reference value for the laser power
- Focal length
- Wave length
- Remarks
Sensor parameters
The following device parameters can be e.g. set here:
- The spatial resolution
- The mechanical movement limits in z-direction
- Selection of one of the measuring devices connected with the bus
- The manual settings of the z-axis
LQM-Adjustment
Not relevant for BeamMonitor BM+
Beamfind settings
Setting parameter for a beamfind procedure. Relevant for BeamMonitor BM+ only.
CCD info
Not relevant for BeamMonitor BM+
CCD settings
Not relevant for BeamMonitor BM+
Power measurement
Opens the measuring window power measurement.
Single...
This menu item enables the start of single measurements, of the monitor mode and
the video mode.
Caustic...
Enables the start of a caustic measurement. Not only automatic measurements but
also serial measurements of manually set parameters are possible. The automatic
measurement starts with a beam search and then caries out the entire measuring
procedure independently. Only the z-range that is to be examined as well as the
desired measuring plane have to entered.
Start adjustment mode
Starts a special monitor mode optimized for the application of the BeamMonitor BM+
for the alignment of laser resonators.