Section V Parameter Function Table
83
S
ect
io
n
V
X1=0% , Y1
=
20% potentiometer 0V corresponding set value: f=Max
frequency*Y1=10.00Hz
X2=50%, Y2
=
50% potentiometer 5V corresponding set value: f=Max
frequency*Y2=25.00Hz
10V
100%
80%
(
X2,Y2)
Y2=50%
100%
X2=50%
X1=0%
(X1,Y1)
AI1,AI2,AI3
x
y
Y1=20%
X1=0%,Y1
=
-100% potentiometer 0V corresponding set frequency:f=Max frequency*Y1=-
50.00Hz
X2=100%,Y2=100%potentiometer 10V correspond set frequency:f=maximum
frequency*Y2=50.00Hz
y
x
AI1,AI2,AI3
Y1=-100%
X1=0%
X2=100%
100%
Y2=100%
(
X2,Y2)
100%
10V
(X1,Y1)
5V
50%
AI2
,
AI3jump as JP6
,
JP7
,
instruction as
:
o12
AI1 input filter time
8000
-
-
-
-
o13
AI2 input filter time
0.00~2.00
s
0.10
Y
o14
AI3 input filter time
8000
0.00~2.00
s
0.10
Y
Filter time constant of analog signal input, that is 0.00~2.00s.If time parameter is set too
long, the changement of setting frequency will be stable, but responsing speed will be slow;If
time parameter is set too short, the changement of setting frequency will not be stable, but
responsing speed will be quick.
o15
o16
DA1 output terminal
DA2 output terminal
No reaction
0
-
-
-
-
Y
Y
Setting frequency
1
Actual frequency
2
Actual current
3
Output voltage
4
DC bus voltge
5
IGBT temperature
6
Output power
7