Appendix I
154
A
p
p
en
d
ix
I
1:JOG running
bit
7 bit
6 bit
5 bit
、
4 bit
Neaning
0:Lower frequency
not arriving
1:Arrive lower
frequency
0:Upper frequency
not arriving
1:Arrive upper
frequency
00:Stopping 01:Accelerating
10:Decelerating 11:Running in a even
speed
bit
3 bit
2 bit
1 bit
0 bit
Meaning
0:Running reverse
1:Running forward
0:Stopping
1:Running
Reserve
0: V/F control
1:SV control
NOTE 3
:
Running command
bit
15 bit
14 bit
13 bit
12 bit
Meaning
Reserve
Rreserve
Reserve
Reserve
bit
11 bit
10 bit
9 bit
8 bit
Meaning
Reserve
Reserve
Reserve
Reserve
bit
7 bit
6 bit
5 bit
4 bit
Meaning
0
:
No free-stop
1:Free-stop
command
Reserve
0
:
JOG stopping
1
:
JOG running
Reserve
bit
3 bit
2 bit
1 bit
0 bit
Meaning
Reserve
0:Reverse command
1:Forward command
Reserve
0:Stop command
1:Run command
NOTE 4
:
Fault style code
Serial.number LED display
Fault message
0
E.OCP
System is disturbed or impacted by instant over current, over current
signal from current inspected circuit or drive circuit
1
Reserve
2
E.OC3
Inverter output current exceeded 3 times of motor rated current
3
Reserve
4
E.OU
Over voltage
5
E.LU
Under voltage
6
E.OL
Over load
7
E.UL
Under load warm
8
E.PHI
Input phase loss
9
E.EEP
EEPROM error
10
E.ntC
Over heat
11
E.dAt
Time limit fault
12
E.Set
External fault