Section V Parameter Function Table
76
Sect
io
n
V
7
6
5
4 3
2 1
0
2
2
2
2
2
2
2
2
0
1
2
3
4
5
6
7
Potentiometer
FWD
STOP
PRG
SET
ESC
MF1
MF2
Key SET+ESC in Keyboard can activate and cancel keyboard lock function.
To lock which key will be decided by corresponding parameter :
Set 0~10 bit
Keyboard locked state
0
0
Unlock FWD key
1
Lock FWD key
1
0
Unlock STOP key
1
Lock STOP key
2
0
Unlock PRG key
1
Lock PRG key
3
0
unlock SET key
1
Lock SET key
4
0
Unlock ESC key
1
Lock ESC key
5
0
Unlock MF1 key
1
Lock MF1 key
6
0
Unlock MF2 key
1
Lock MF2 key
7
0
Unlock potentiometer
1
Lock potentiometer
A38
UP/DN control
1 bit
Power down to save
0
-
0000
Y
Power down to clear
saving
1
10 bit
Saving after stopping
0
Stop command to clear
saving
1
Cleared at the end of
stopping
2
100 bit
One-direction adjustment
0
Double-direction
adjustment
1
1000bit Invalide adjustment
0