Page 82 of 89
(PVI-6000-OUTD-xx-AU Rev:1.0)
Description
Value
PVI – 6000-OUTD
Recommended DC power
6200W
Nominal input voltage
360Vdc
Max. absolute input voltage
600Vdc
Input voltage, MPPT operating
range
90 Vdc to 580 Vdc
Input voltage, MPPT operating
range at full power
180 Vdc to 530 Vdc
Max. short circuit current (of
each array)
22 Adc
Max. operating input current
(of each array)
18 Adc
Max. input power (of each
array) (*)
4000 W
PV Ground fault protection
Ground fault detector and interruption provided
Input channels configuration
(array)
Two independent
MPPT channel with
shared negative
poles
Two channels in
parallel
(*)
Total DC power input must always be below the recommended DC power
NOTE:
If the input current supplied by the photovoltaic field connected
to the inverter is above the max. value and the input voltage is within the
allowed range, the inverter is not damaged.