Page 53 of 89
(PVI-6000-OUTD-xx-AU Rev:1.0)
5.5.3
First phase - electric parameter check
A FEW POINTERS ON DISPLAY KEY OPERATION:
During regular operation, the display will cycle through available data. The display
changes to a different screen every 5 seconds, or screens may be scrolled manually
by pressing the UP (2nd key from display) and DOWN keys (3rd key from
display).
Either way, pressing the ESC key (right next to the display) calls back the previous
menu.
Fig.20
Fig.21
Auto-scroll is indicated by 2 arrows in the top left corner of the display (Fig.20).
To stop auto-scroll, press the
ENTER
key (4th key from display). A padlock will
appear (Fig.21).
1A) If the measurements taken previously (see sect. 5.5.1) are found to be correct,
the system will proceed to the next checks. The 12 screens outlined below are
shown alternately as mentioned in section
“A FEW POINTERS ON DISPLAY
KEY OPERATION”.
2A) shows inverter serial number and firmware revision level.
3A)
E-tod : Daily energy output.
$-tod: Daily energy savings. Value is expressed in the set currency.
Type OUTD
PN------------
S/N--------- xxxxxx
FW rel. C.0.1.1
E-tod 0 Wh
$-tod 0.0 EUR
Summary of Contents for AURORA PVI-6000-OUTD-AU Series
Page 16: ...Page 16 of 89 PVI 6000 OUTD xx AU Rev 1 0 Fig 3C Integrated switch and diodes models...
Page 39: ...Page 39 of 89 PVI 6000 OUTD xx AU Rev 1 0 Fig 18 Data Transmission Options...
Page 70: ...Page 70 of 89 PVI 6000 OUTD xx AU Rev 1 0...
Page 88: ...Page 88 of 89 PVI 6000 OUTD xx AU Rev 1 0 CERTIFICATE OF CONFORMITY...