Page 34 of 89
(PVI-6000-OUTD-xx-AU Rev:1.0)
3.7.
How to access the internal terminal boards through the front panel
WARNING
: Shock hazard! Before removing the front panel, disconnect
AURORA at both the AC and DC side and allow 5 minutes for the
internal capacitors to discharge.
To remove the front panel, unscrew the 4 screws shown in figure 14 using the
supplied flat-blade screwdriver.
Fig.14 AURORA with front panel
After refitting the front panel, tighten the screws to 1.5 Nm (13.2 in-lbs) as a
minimum to ensure proper sealing.
3.8.
Replacing the CR2032 lithium battery
Aurora incorporates a CR2032 lithium battery. When the battery is nearing the end
of its life, a corresponding message appears on the LCD display.
Remove the front panel (see fig.15) to expose the battery.
Please note that the battery will not fit into its mount from the top down; slide the
battery into its mount from side A, while holding it tilted at a 30° angle. The
battery will slide into place into the battery mount.
1
2
3
4