Appliance Category
CAT I
2H
4.0 Technical Data
7
Horizontal
Flue Terminal
Diameter
110mm
Dimensions
Projection
150mm
Outercase Dimensions
Overall Height
Inc Flue Elbow
-
1000mm
Casing Height
-
850mm
Casing Width
-
490mm
Casing Depth
-
325mm
Weights
kg
lb
Packaged Boiler Carton
54.7
120.6
Packaged Flue Kit
3.6
8.0
Weight Empty
49.4
108.9
Installation Lift Weight
41
90.4
Connections
copper tails
Gas Supply
-
22mm
Central Heating Flow
-
22mm
Central Heating Return
-
22mm
Pressure Relief Discharge -
15mm
Condensate Drain
-
1 in BSP
Recommended System
Temperature Drop
Normal
11°C
20°F
Condensing
20°C
36°F
Heat Input
Max
Min
kW
33.76
10.2
Btu/h
115,200
34,840
Heat Output
(Non Condensing 70° C Mean Water Temp)
Max
Min
kW
30.18
9.14
Btu/h
102,980
31,180
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
200W
External Fuse Rating
3A
Internal Fuse Rating
(BS 4265)
Fuse (2)
4 AT (Control Board)
Fuse (3)
2 AT (Ignition Board)
Inlet Pressure
(Natural Gas)
Min
18.1 mbar
Max
22.5 mbar
(see Section 10.1)
Injector
(Natural Gas)
6.3mm Diameter
Clearances
(For unventilated compartments see Section 7.5)
Both Sides
5mm Min
Above Casing
200mm Min
Below Casing
200mm Min
Front (For Servicing)
500mm Min
Front (In Operation)
5mm Min
Appliance Type
C
13
C
33
Nox Class
5
Heat Output
(Condensing 40° C Mean Water Temp)
Max
Min
kW
32.61
10.1
Btu/h
111,280
34,520
Water Content
litres
3.5
pints
6.2
Controls
boiler thermostat, safety thermostat,
flow switch, electronic flame sensing,
temperature protection thermostat &
condensate blockage sensor.
Central Heating Primary
Circuit Pressures
bar
lb/in
2
Safety Discharge
3
43.5
Max Operating
2.5
36.3
Min Operating
1
10.9
Recommend Operating
1-2
14.5-29
Expansion Vessel -
(For Central Heating
only. Integral with appliance)
bar
lb/in
2
Min Pre-charge Pressure
0.95
13.6
Nominal Pre-charge
Pressure
1
14.5
litre
gal
Max Capacity of
CH System
125
27.5
0
120
240
360
480
100
200
300
400
500
600
Pump Head (mbar)
Flow Rate (l/h)
Central Heating Circuit available Pump Head
0
600
720
840
Where flow rates are required in excess of 840 l/h, please refer to page 21.
This value is used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been
certified by 0086.
SEDBUK Declaration For
Potterton Promax System HE
The seasonal efficiency (SEDBUK) is 90.9 %
Max Gas Rate
(Natural Gas)
(After 10 Mins)
Btu/hr
102,980
75,000
m
3
/h
2.95
2.36
ft
3
/h
104.2
83.3
NOTE:
The maximum output of the
boiler is factory set at 22.0kW
(75,000 Btu/hr). This can be altered
to 30.18kW (102,980 Btu/hr)
- see section 8.7.