14.0 Fault Finding
39
Is
boiler supply
fuse OK ?
Is there
230 V at mains
input terminal
block
(A)
?
Is
there 230 V at
mains input connection
to control PCB
(B)
?
Is
there 230 V at
control PCB transformer
mains connection
(C)
?
Is
control PCB
fuse F2 OK ?
Is wiring
from control PCB
to interface PCB
OK
(E)
?
Does
boiler produce
heat ?
Replace with 3A fuse.
No mains supply to
boiler.
Wiring from mains input
terminal block to control
PCB faulty.
Replace control PCB.
Replace transformer.
Check for short circuits
on control PCB and fan.
If OK replace fuse.
Rectify wiring
Replace control PCB.
Replace interface PCB.