7.0 Site Requirement
16
Key
Accessory
Size
Baxi Code
Number
Concentric Flue System 110mm diameter
A
Straight extension kit
1000mm
241695
500mm
241694
250mm
241692
B
Bend kit
93°
241687
C
Bend kit (pair)
45°
241689
D
Horizontal flue terminal
243013BAX
Clamp
110mm
243014BAX
Twin Flue System 80mm diameter
E
Straight extension kit
1000mm
238690
500mm
238692
250mm
238694
F
Bend kit
90°
246139
G
Bend kit (pair)
45°
246138
Universal Vertical Flue Kits
H
Twin flue adaptor kit
242757
J
Vertical flue terminal
242802
K
Universal roof tile
25°/50°
243015
L
Roof cover plate kit
243131
M
Flat roof flashing
243016BAX
N
Boiler connection vertical concentric
242886
Clamp
80mm
238684
7.13
Flue options
Concentric
The maximum equivalent lengths are 4m
(horizontal) or (vertical). There lengths exclude the
standard elbow and flue/terminal assembly
(horizontal) and terminal assembly (vertical).
Twin Flue
The total maximum equivalent flue length is 150m.
NOTE:
Each 1m of flue duct should be calculated
as 2m.
Any additional “in line” bends in the flue system
must be taken into consideration. Their equivalent
lengths are:
Concentric Pipes: 45° bend
0.5 m
93° bend
1.0 m
Twin Flue Pipe:
45° bend (air duct)
1.3 m
45° bend (flue duct)
2.6 m
90° bend (air duct)
4.8 m
90° bend (flue duct)
9.6 m
Detailed examples of equivalent flue length
calculation are given in the Installation Guidance
Notes for each flue system type.
(Documents 243501 and 243502 for concentric and
twin pipe respectively).
Standard Flue
C
D
A
B
J
K
C
L
H
E
H
M
G
F
N