background image

Page 18

www.poolpro.com.au

2. 

Press 

 or 

 to adjust the setting between ON or OFF, then press 

 to save.

To set the run time of the pH Controller:

The run time is programmed automatically when setting up the volume of the swimming 

pool in the chlorinator. The system calculates how many minutes per day your Neptune 

pH Controller runs based on the volume of your pool. This can be changed manually.

1. 

“Run Time” will flash. Press 

 to enter the Run Time settings. To adjust the run 

time press 

 or 

 then press 

 to save (and return to the Main Screen) or 

press   to exit without saving.

NOTE: Some states use undiluted acid to feed the pH Controller (i.e. there is no 

container with a 1:3 mix). In this case the operator needs to manually change the run 

time from the displayed result to an approximate 1/4 of this reading. For example if 

15min/day is displayed then change this to 4min/day.

To set the demand or prime quantity of the pH Controller:

The demand or prime quantity can be manually adjusted from 0-5000ml. This function 

is useful for priming tubes after an acid drum change, or adding the required acid from 

your acid demand test.
IMPORTANT: Enter the exact amount from your test result in ml (e.g. 500ml) and the 

system automatically adds 4 times that amount, thereby allowing for the  

1:3 ACID:WATER mix ratio in the acid drum.
If you are now back in the Main Screen, go back into the pH Control Mode:

1. 

Press the 

 button to enter the Main Menu. Press 

 or 

 to scroll through the 

menu. Press 

 to select pH Control Mode. Press 

 or 

 to scroll to Demand 

or Prime and press 

.

2. 

Press 

 or 

 to adjust the ml quantity then press 

 to save. The peristaltic 

pump starts turning and a time-based reading starts flashing and counting down. If 

desired, you can lower the time by pressing 

 then pressing 

 to confirm.

3. 

If the tubes/lines are primed, you can stop the peristaltic pump by pressing 

 

while in the DOSE TIME LEFT menu, until the time left reaches 0, then press 

 to 

confirm. Press 

 to return to the Main Screen.

To turn off the pH Control mode:

1. 

Press the 

 button to enter the Main Menu. Press 

 or 

 to scroll through the 

menu. Press 

 to select pH Control Mode.

2. 

Press 

 or 

 to scroll until “pH Mode: ON” is flashing, then press 

3. 

Press 

 or 

 to select “OFF”, then press 

 to save.

Summary of Contents for Neptune NDC15

Page 1: ......

Page 2: ...Button Salt Test 13 14 12 6 Shortcut Button Backwash 14 15 13 Main Menu 15 13 1 Main Menu Backwash 15 13 2 Main Menu Brightness 15 13 3 Main Menu Cell Cleaning 15 13 4 Main Menu Chlor Boost 16 13 5 M...

Page 3: ...ions on your recent purchase of your Neptune Digital Salt and Mineral Chlorinator Thank you for supporting Pool Pro Products Please take a moment to read through the entire manual before installing yo...

Page 4: ...tion on a particular subject s in good faith and is not an exhaustive treatment of such subject s Its use is beyond the control of the author contributor publishers and distributors and should not be...

Page 5: ...this does not mean you need more salt There will always be less chlorine demand in colder water For salt only We recommend adding 3 5kg of pool salt per 1000 litres of pool water For minerals magnesi...

Page 6: ...e chlorinator unit Weekly T A Total Alkalinity Concrete 80 150ppm Fibreglass Vinyl 80 120ppm Add Pool Pro pH Buffer Add Pool Pro Hydrochloric Acid Fortnightly Calcium Hardness Concrete 250 300ppm Fibr...

Page 7: ...do not allow gases generated from the Cell to collect and build up in any part of the installation It is RECOMMENDED that the Cell Housing be installed horizontally to create a natural gas trap that a...

Page 8: ...Plugs and Screws provided The Power Pack should be mounted no further than 1 5m from the Chlorinator Cell for ease of operation 8 INSTALLING THE CELL Connect the Cell Housing horizontally in the retu...

Page 9: ...e Runs a backwash process to clean the media inside the pool filter system Enters the Main Menu if pressed when the LCD screen is displaying the Main Screen see section Main Screen on page 9 Saves any...

Page 10: ...es for your chlorinator to operate a 2 CYCLES DAY 6am 10am and 4pm 8pm b 1 CYCLE AM 8am 4pm c 1 CYCLE PM 8pm 4am 3 Press to save or press to exit without saving If these cycle times are not suitable y...

Page 11: ...on the Main Screen for the shortcut buttons to function 12 SHORTCUT BUTTONS 12 1 SHORTCUT BUTTON POWER MODE This function changes the operating mode of the chlorinator AUTO running on the timer settin...

Page 12: ...flash Press or to adjust the hour Press to save 4 The minutes will flash Press or to adjust the minutes 5 Press to save or press to go back to the hours Press again to exit without saving TIMER SETTI...

Page 13: ...Press again to exit without saving 6 If you chose SINGLE CYCLE you will be taken back to the Main Screen If you chose DUAL CYCLE continue to the next step 7 To set the ON START time for TIMER 2 TIMER...

Page 14: ...able for cartridge filters 3 Press to begin the backwash cycle The pump will start and run for 2 minutes A countdown timer will display on the LCD screen Press to increase the run time by 1 minute if...

Page 15: ...ervice Menu 12 Spa Mode 13 Winter Blanket Mode 14 pH Control Mode See Section 12 6 on pages 14 15 SHORTCUT BUTTON BACKWASH 13 1 MAIN MENU BACKWASH 13 2 MAIN MENU BRIGHTNESS This function adjusts the b...

Page 16: ...f the LCD screen 1 Press the button to enter the Main Menu Press or to scroll through the menu Press to select Contrast 2 Press or to adjust the contrast 3 Press to save or press to exit without savin...

Page 17: ...mation regarding the Service Menu 13 12 MAIN MENU SPA MODE This function allows you to adjust the settings for a spa 1 Press the button to enter the Main Menu Press or to scroll through the menu Press...

Page 18: ...s useful for priming tubes after an acid drum change or adding the required acid from your acid demand test IMPORTANT Enter the exact amount from your test result in ml e g 500ml and the system automa...

Page 19: ...cium build up is present use Pool Pro Cell Cleaner to clean the cell We do not recommend the use of Hydrochloric Acid to clean the cell 6 Check the cell s O Ring is clean greased with silicone grease...

Page 20: ...ll chamber of water is passing over the cell You may need to backwash your filter See Backwash Pages 14 15 The cell could be damaged or at the end of its life Damaged coating will reduce cell life and...

Page 21: ...o wall outlet and outlet is turned on Plugged into power point and turned on but still no power Test wall outlet with a working appliance Wall outlet working but still no power Check circuit breaker a...

Page 22: ...chamber of water is passing over the cell You may need to backwash your filter See Backwash Pages 14 15 The cell could be damaged or at the end of its life Damaged coating will reduce cell life and ou...

Page 23: ...Page 23 www poolpro com au 16 SCHEMATICS...

Page 24: ...re Entry 13 PPN00869 Cable Grommet 6N 4 14 PPN00501 Grommet Rubber Aux Hole Up To 19mm 15 PPN00488 Cell Plug SL 10 Male End Complete With Power Supply Looms Grease Filled 16 Neptune Screw Stainless M3...

Page 25: ...l Only 62 PPN00379 3 Way Cell Housing Smokey 63 OR950M Cell Housing NDC O Ring EPDM Rubber 64 PPN00380 Cell Cap Locking Ring NDC 65 PPSCCAP Cell Cap Includes Cable Cover Cap Brassware Washers Resin Fi...

Page 26: ...bient temperature or any condition that adversely affects the performance of the equipment will render this warranty null and void 3 Defective equipment must be returned to the manufacturer or dealer...

Page 27: ...to submit a warranty request The warranty is void under the following circumstances Installation is carried out incorrectly by any person other than a person authorised by us to do so The Power Pack o...

Page 28: ...More products in the Neptune range PUMPS FILTERS CHLORINATORS CLEANERS LIGHTS...

Reviews: