Commissioning
Operating Manual PMI 6 primo
1004647-EN-02
33
Alternative 2: The IP settings are unknown
}
Prerequisite: The PMI 6 primo and the PC are in the same broadcast domain.
1. Select
Ethernet
.
2. Click on
Network scan
.
3. Select the required network adapter.
4. Click on
Scan
.
5. From the list, select the subscriber to which you wish to connect.
Note: Click on
Ping
to identify the device's hardware.
6. Select
Configuration…
The
Device Configuration
window opens.
7. Enter the IP settings and then select
Use this IP address
. The
Connection Wizard
window opens.
8. Select
Finish
.
The network subscriber is connected.
The motion control software reports on the configuration, once the Ethernet connection has
been established.