Manual MCD
+
In the Rotary switch mode, you can be change between 2 ranges (
I
or
II
) by the rotary
switch ‘Current range setting’:
Fig. 7: Range
I
:
max. 1.6 A
r.m.s.
in 0.1 A steps
Fig. 8: Range
II
:
max. 5 A
r.m.s.
in 0.3 A steps
Remark:
The switch positions may be changed
•
while the MCD is powered off or
•
the power stage is deactivated. However, after changing the switch position the
power stage should be reset by the input Reset.
1.5.2 ServiceBus Mode
The ServiceBus mode is only activated, if all three rotary switches S2, S3 and S4 are set
to
‚0’
. The rotary switch S1 addresses the device (0…F).
Important:
Each address must only be used once!
Fig. 9: ServiceBus Mode
MA 2102-A005 GB
10